-40%

Implant System Dental Surgical Brushless Motor W/ Gutta Percha Tooth Plus USA

$ 11.61

Availability: 67 in stock
  • Return shipping will be paid by: Buyer
  • MPN: ZZ1700000300
  • Modified Item: No
  • Brand: AZDENT
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Item must be returned within: 60 Days
  • Custom Bundle: No
  • Condition: New
  • California Prop 65 Warning: Stainless Steel
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Adjustable torque range: 5.0-55N.cm(20:1)
  • Intended Use/Discipline: Dental Laboratory

    Description

    Every time before the high temperature and high pressure sterilization, must put prevent steam bolt on motor please
    Features:
    Technical:
    Maximum output power: 120W
    Power:110V/220V, 50HZ/60HZ
    Adjustable torque,range: 5.0-55N.cm (20:1)
    BLDC Speed:
    300
    rpm-
    50000
    rpm
    Infusion flow(maximum): 150ml/min
    Motor: Original switzerland surgical brushless motor
    Features:
    1-Reduction geared contra angle with internal and external irrigation
    -Standard push button reduction geared contra angle
    -Available for standard reduction handpiece
    -Available for standard reduction handpiece
    -Autoclave repeatable
    2-Original switzerland surgical brushless motor
    -Speed is from
    300
    rpm to
    50000
    rpm
    ,
    high torque and wide speed range for all kinds of treatment.
    -Maximum torque is 55N.cm.Powerful torque output can be efficient cutting bone.
    -Unmatched stability,no overheating, silent
    3-Foot control pedal
    -Multi functional foot pedal, could achieve all the operating functions.
    -Easy and flexible.
    4-Intelligent cooling system
    -Hand control and foot control
    -Inner and external channel cooling and wash
    -Quiet and strong water pump
    5-High Performance control system
    -Big LED Screen, control easy.
    -10 kinds of the reduction contra angle to choose.
    -10 setting program, preset the speed of air motor

    cool down the liquid amount and torque, reverse and specific speed.
    -Achieve stepless speed regulation.
    Packing list:
    1X major control unit
    1X foot pedal
    1X Power cord
    1X motor with wire
    1X water supply bottle holder
    1X motor holder
    8X pipe clasp
    1X Y type isocon
    1X internal waterspray nozzle
    1X contra angle speed reducing handpiece for implant
    1X prevent steam bolt
    5
    X
    irrigation tube
    1X nozzle for contra angle
    =============================================================================
    Operation of the Main Unit
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
    4. After the Main Unit and ball head are perfectly fit together, plug in the international standard
    electrical source, grounding is strongly recommended.
    5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit
    will show the fore setting time. Now the equipment is in standby mode.
    6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time
    as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting
    mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when
    the time is adjusted the light lamp is off. The equipment is now in standby mode.
    7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
    9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
    10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
    11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot
    lamp is off. Don't keep the main unit long in standby mode.
    Points for Attention
    1.
    Make sure the angle of film, tooth, and b
    all head are properly aligned when taking a picture. Keep them steady until the last step of picturing;
    making sure that there is no change in any of their positions.
    2.
    Remember to turn the power offwhen work is done.
    3.
    Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
    4.
    After turning the power on, wait one minute before taking pictures, this allows the ray to provide a
    steady output.
    5.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this
    occurs, it will not be able to carry out the normal work of filming.
    6.
    When taking pictures, the EXP button could stop the objection and then the machine goes back to the
    preparation mode.
    7.
    Use high quality tooth film and developing liquid to make clear pictures.
    8. Handle the ball head gently while in use, so as not to damage the delicate component.
    9.
    Do not pull hard on the cable which connects the ball head to the main unit.
    10.
    The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
    11.
    We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output
    is 0.2-0.5 seconds.
    12.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    13.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
    14.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    15.
    Other requests accordance with the scope of the technical parameters.
    16.
    Please read the manual carefully before using.
    SHIPPING FROM US TO US ,FROM CHINA TO OTHER COUNTRIES
    FDA STATEMENT:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
    Dear :
    About X-ray machine battery problem, lithium battery inside needs to keep active and can’t be stored for a long time without usage,which can lead to power failure.If it is not used for a long time, they are advised to discharge properly, (turn on the screen or expose several times), then charge about one hour.
    ============================================================================
    Dental Endodontics Treatment Reciprocation Endo Motor 9 Program Settings
    Description:
    9 program settings can be memorized
    Auto-reverse mode makes operation easier
    Cordless handpiece delivers freedom of movement
    Non-contact type charge design, more safe and reliable
    High capacity lithium-ion battery provides stable and prolonged usage
    With 16:1 electric contra angle (1:1/10:1/16:1/20:1 contra angle can be compatible for wide clinical application)
    Offers quick and easy coupling
    Automatic power off
    TECHNICAL SPECIFICATIONS:
    Ration
    RPM
    Torque(N.cm)
    1:1
    2000 - 9000
    ----
    10:1
    200 - 900
    0.2 - 2.2
    16:1
    140 - 550
    0.3 - 3.0
    20:1
    100-450
    0.4 – 4.0
    Main engine Voltage: 3.7V
    Main engine Battery capacity: 1050mAh
    Charger input voltage: AC110-220V,50-60Hz
    Charger onput voltage:5V
    Output current: 1000mA
    Auto-Reverse mode instructions:
    Auto reverse (When resistance higher than torque, the quipment will auto-reverse. And auto-reverse again till the resistance lower than torque)
    Auto stop (When resistance higher than torque, the equipment will stop working)
    Auto reverse & stop (When resistance higher than torque, the equipment will auto-reverse.)
    And stop after resistance disappeared.
    =====================================================================
    Obturation Pen
    Temperature sensor IC type
    Heating time 2 Seconds
    Temperature range 150-350 ℃
    Charging system
    Operating Voltage DC.3.6V
    Adaptor Input: AC 100-240V
    Output: DC 4.5V
    Charging time 4 hours
    Continuous heat-up time for gun after fully charging 60 minutes
    Continuous heat-up time for pen after fully charing 30 minutes
    Battery (Li-on)
    Capacity: DC3.6 V 2.2AH
    Dimension: φ19 *65 (3pcs total)
    Operating condition: Temperature 5℃-40℃
    Packing List:
    Obturation Pen-----1 PC
    Stand for pen-----1 PC
    Pen Tip (Type F/FM/M/ML)-----4PCS
    Charging base-----1 PC
    Charger-----1PC
    The goods you odered will be posted out in the second working day after the paymet has been made.
    (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be
    monitored and the track of the item will be posted on paypal.